  • J9263A

    HP PROCURVE 6600-24G SWITCH

    P/N: J9263A
    EAN:   8844200757836
    0884420075783
    0884420075752
    8844200757522
    0884420075776

    Manufacturer: Hewlett Packard Enterprise

    Ask our experts about:

    - the equivalent of a third-party
    - The same product in a different than the new state (eg, refurbished)
    - Other / alternative solution

    Condition

    new
    Available options:

    Availability

    Price and flexible funding

    Negotiate the price if:

    - you don't fit in your budget
    - you buy more than one piece
    - you are our regular customer
    - to check how flexible our prices are!

    Find out about our
    pricing
    Are you a Reseller?

    We can offer you additional benefits and long-term cooperation! Contact us for more details !

    Help Zone

    GRATIS

    Consultations

    Call us: +48 71 738 25 31

    Mail us: office@112it.com

    > we'll advise you in your selection
    > we'll rescue your IT project
    > we'll search the whole world for you!

    Adjust further:

    Think about selecting the option for the equipment you wish to purchase.

    portoflio have the option not only to the current models offered by the manufacturer, but also to older models that are no longer produced.

    Additional information

    Other featuresMemory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, packet buffer size: 18 MB QDR SDRAM total (for all 1-GbE ports), 256 MB compact flash, 256 MB DDR SDRAM
    Power requirements100 -120 VAC / 200 -240 VAC; 50 /60 Hz\nThe switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz
    Power supply type1 x J9269A
    MountingTelco rack: Mounts in an EIA-standard 19-in. 2-post telco rack or equipment cabinet; horizontal surface mounting only. Rack kit: Rack rails are required for mounting in HP 10000 Series 4-post racks.
    Remote administrationcommand-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
    Input frequency50 / 60 Hertz
    Input voltage100-120 / 200-240 VAC Volt
    Connectivity technologyWired
    Dimensions (WxDxH)546.1 x 442.5 x 43.2 millimeter
    Latency1000 Mb Latency: < 3.4 µs (FIFO 64-byte packets)
    Management platformHP PCM+; HP PCM (included); command-line interface; Web browser; configuration menu
    Power over Ethernet (PoE)Power over Ethernet (PoE) supportNie
    MemoryInternal memory256 megabyte
    Flash memory256 megabyte
    Operational conditionsOperating temperature (T-T)41 - 104 Fahrenheit
    Storage temperature (T-T)-40 - 70 degrees Celcium
    Operating temperature (T-T)5 - 40 degrees Celcium
    CertificatesElectromagnetic compatibilityFCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
    SafetyCSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950
    Technical detailsElectromagnetic immunityEN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3
    Electrical enhancementsThe switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz
    Supported protocolsRFC 1591 DNS (client); HTML and telnet management\nRFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB\nMIBs\nIP multicast\nIEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP (Premium License); RFC 4675 RADIUS VLAN & Priority\nRFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2461 IPv6 Neighbor Discovery; RFC 2462 IPv6 Stateless Address Auto-configuration; RFC 2463 ICMPv6; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4541 IGMP & MLD Snooping Switch\nIEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON\nNetwork management\nGeneral protocols\nSecurity\nIEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv2 Secure Shell\nIPv6\nDevice management\nOSPF\nRFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF)\nRFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA\nRFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
    Processor clock speed666 megahertz
    Built-in processorPowerPC 8540
    StackableTak
    PowerPower consumption (typical)159.7 Watt
    Weight & dimensionsWeight16.7 lb. pounds
    Weight7580 gram
    ProtocolsSupported network protocolsRFC 1591 DNS (client); HTML and telnet management; IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058; RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP; \nRFC 4675 RADIUS VLAN & Priority; RFC 3376 IGMPv3 (host joins only); \nRFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License); RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6; RFC 4541 IGMP & MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA; RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF); IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting.
    Data transmissionMaximum data transfer rate1 gigabit per second
    Throughputup to 35.7 million pps (64-byte packets) Million packets per second
    MAC address table10000 entries
    NetworkingFlow control supportTak
    Link aggregationTak
    IGMP snoopingTak
    Full duplexTak
    Networking standardsIEC 61000-3-2; Flicker: EN 61000-3-3
    Ports & interfacesI/O ports20 auto-sensing 10/100/1000 ports(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T), Media Type: Auto-MDIX, Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only; 4 dual-personality ports, each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers); 1 RS-232C DB-9 console port
    Basic switching RJ-45 Ethernet ports quantity24
    Management featuresSwitch typeManaged